Comparing AG-39
For AG-39, compare these listed entries: Using voltage range: AG-39DF: 10~30V / DC · AG-39N/AG-39NB/AG-39P/AG-39PB: 5~30V / DC;Sensitiveness: AG-39DF: 40~800 Gaussian · AG-39N/AG-39NB: 40~800 Gaussian · AG-39P/AG-39PB: 25~800 Gaussian. Check wiring and interface information for that variant. A shared series page does not establish interchangeability or compatibility with another component.
Parameters and where they apply
| Consumption current AG-39N/AG-39NB · AG-39P/AG-39PB · Source suffix-model group; check the exact model | 3mA Max.@24V |
|---|---|
| Indicator light AG-39DF · Source suffix-model group; check the exact model | Red LED |
| Indicator light AG-39N/AG-39NB · Source suffix-model group; check the exact model | Red LED |
| Indicator light AG-39P/AG-39PB · Source suffix-model group; check the exact model | Green LED |
| Leakage current AG-39DF · Source suffix-model group; check the exact model | 90μA Max.@28V |
| Leakage current AG-39N/AG-39NB · AG-39P/AG-39PB · Source suffix-model group; check the exact model | 0.01 mA Max |
| Logic AG-39DF · Source suffix-model group; check the exact model | Electronic; Normally open type |
| Logic AG-39N/AG-39NB · AG-39P/AG-39PB · Source suffix-model group; check the exact model | Electronic; Normally open/normally closed |
| Maximum contact capacity AG-39DF · Source suffix-model group; check the exact model | 1.5W |
| Maximum contact capacity AG-39N/AG-39NB · AG-39P/AG-39PB · Source suffix-model group; check the exact model | 3W |
| Protection circuit AG-39DF · Source suffix-model group; check the exact model | Surge absorption protection |
| Protection circuit AG-39N/AG-39NB · AG-39P/AG-39PB · Source suffix-model group; check the exact model | Power polarity reverse protection, surge absorption protection |
| Residual pressure drop AG-39DF · Source suffix-model group; check the exact model | 2.65V Max.@50mA DC |
| Residual pressure drop AG-39N/AG-39NB · AG-39P/AG-39PB · Source suffix-model group; check the exact model | 0.5V Max.@200mA DC |
| Sensitiveness AG-39DF · Source suffix-model group; check the exact model | 40~800 Gaussian |
| Sensitiveness AG-39N/AG-39NB · Source suffix-model group; check the exact model | 40~800 Gaussian |
| Sensitiveness AG-39P/AG-39PB · Source suffix-model group; check the exact model | 25~800 Gaussian |
| Switching frequency AG-39DF · Source suffix-model group; check the exact model | 900Hz |
| Switching frequency AG-39N/AG-39NB · AG-39P/AG-39PB · Source suffix-model group; check the exact model | 900Hz |
| temperature range AG-39DF · Source suffix-model group; check the exact model | -10°~70℃ |
| temperature range AG-39N/AG-39NB · AG-39P/AG-39PB · Source suffix-model group; check the exact model | -10°~70℃ |
| Type AG-39DF · Source suffix-model group; check the exact model | Two wire contactless type |
| Type AG-39N/AG-39NB · AG-39P/AG-39PB · Source suffix-model group; check the exact model | Three wire contactless NPN type |
| Using switch current AG-39DF · Source suffix-model group; check the exact model | 1~50mA |
| Using switch current AG-39N/AG-39NB · AG-39P/AG-39PB · Source suffix-model group; check the exact model | 0~200mA |
| Using voltage range AG-39DF · Source suffix-model group; check the exact model | 10~30V / DC |
| Using voltage range AG-39N/AG-39NB · AG-39P/AG-39PB · Source suffix-model group; check the exact model | 5~30V / DC |