Comparing AL-39
For AL-39, compare these listed entries: Using voltage range: AL-39DF: 10~28V / DC · AL-39N/AL-39NB/AL-39P/AL-39PB: 5~30V / DC;Sensitiveness: AL-39DF: 40~800 Gaussian · AL-39N/AL-39NB: 40~800 Gaussian · AL-39P/AL-39PB: 25~800 Gaussian. Check wiring and interface information for that variant. A shared series page does not establish interchangeability or compatibility with another component.
Parameters and where they apply
| Consumption current AL-39DF · Source suffix-model group; check the exact model | 40μA Max.@24V |
|---|---|
| Consumption current AL-39N/AL-39NB · AL-39P/AL-39PB · Source suffix-model group; check the exact model | 7.5mA Max.@24V |
| Indicator light AL-39DF · Source suffix-model group; check the exact model | Red LED |
| Indicator light AL-39N/AL-39NB · Source suffix-model group; check the exact model | Red LED |
| Indicator light AL-39P/AL-39PB · Source suffix-model group; check the exact model | Green LED |
| Leakage current AL-39DF · Source suffix-model group; check the exact model | 90μA Max.@28V |
| Leakage current AL-39N/AL-39NB · AL-39P/AL-39PB · Source suffix-model group; check the exact model | 0.01 mA Max |
| Logic AL-39DF · Source suffix-model group; check the exact model | Electronic; Normally open type |
| Logic AL-39N/AL-39NB · AL-39P/AL-39PB · Source suffix-model group; check the exact model | Electronic; Normally open/normally closed |
| Maximum contact capacity AL-39DF · Source suffix-model group; check the exact model | 1.4W |
| Maximum contact capacity AL-39N/AL-39NB · AL-39P/AL-39PB · Source suffix-model group; check the exact model | 6W |
| Protection circuit AL-39DF · Source suffix-model group; check the exact model | Surge absorption protection |
| Protection circuit AL-39N/AL-39NB · AL-39P/AL-39PB · Source suffix-model group; check the exact model | Power polarity reverse protection, surge absorption protection |
| Residual pressure drop AL-39DF · Source suffix-model group; check the exact model | 2.65V Max.@50mA DC |
| Residual pressure drop AL-39N/AL-39NB · AL-39P/AL-39PB · Source suffix-model group; check the exact model | 0.5V Max.@200mA DC |
| Sensitiveness AL-39DF · Source suffix-model group; check the exact model | 40~800 Gaussian |
| Sensitiveness AL-39N/AL-39NB · Source suffix-model group; check the exact model | 40~800 Gaussian |
| Sensitiveness AL-39P/AL-39PB · Source suffix-model group; check the exact model | 25~800 Gaussian |
| Switching frequency AL-39DF · Source suffix-model group; check the exact model | 1000Hz |
| temperature range AL-39DF · Source suffix-model group; check the exact model | -10°~70℃ |
| temperature range AL-39N/AL-39NB · AL-39P/AL-39PB · Source suffix-model group; check the exact model | -10°~70℃ |
| Type AL-39DF · Source suffix-model group; check the exact model | Two wire contactless type |
| Type AL-39N/AL-39NB · AL-39P/AL-39PB · Source suffix-model group; check the exact model | Three wire contactless PNP type |
| Using switch current AL-39DF · Source suffix-model group; check the exact model | 1~50mA |
| Using switch current AL-39N/AL-39NB · AL-39P/AL-39PB · Source suffix-model group; check the exact model | 0~200mA |
| Using voltage range AL-39DF · Source suffix-model group; check the exact model | 10~28V / DC |
| Using voltage range AL-39N/AL-39NB · AL-39P/AL-39PB · Source suffix-model group; check the exact model | 5~30V / DC |