← Back to Pressure-sensor series
ECA-LCF4D source product illustration
Model reference ECA-LCF4D source product illustration Open full-resolution source image
ECA-LCF4D source product illustrationECA-LCF4D · housing

Pressure sensors · Pressure-sensor series

ECA-LCF4D

ECA-LCF4D belongs to Pressure-sensor series in the Pressure sensors catalog.

Series
Pressure-sensor series
Configurations
None listed; specify yours in the inquiry

ECA-LCF4D · Pressure sensors

Begin with the quantity to measure, required measuring range and the mechanical load connection. Compare the sensing element with the equipment mounting and signal path.

Comparing ECA-LCF4D

For ECA-LCF4D, read Cable, Comprehensive accuracy, ΦA by the parameter group and variant shown. Use the exact sensor variant and its calibration and electrical information. Review mounting, cable routing and the operating environment before connecting the measurement chain.

Parameters and where they apply

Cable

Current technical model · Technical parameters:; Source row: Cable

Four core shielded cable
Comprehensive accuracy

Current technical model · Technical parameters:; Source row: Comprehensive accuracy

±0.1%F.S
ΦA

Current technical model · Selection Guide ; Source row: 0.2; Source column: ΦA

58 mm
ΦB

Current technical model · Selection Guide ; Source row: 0.2; Source column: ΦB

16 mm
ΦD

Current technical model · Selection Guide ; Source row: 0.2; Source column: ΦD

45 mm
E

Current technical model · Selection Guide ; Source row: 0.2; Source column: E

10.57 mm
F

Current technical model · Selection Guide ; Source row: 0.2; Source column: F

6.5 mm
H

Current technical model · Selection Guide ; Source row: 0.2; Source column: H

24 mm
H1

Current technical model · Selection Guide ; Source row: 0.2; Source column: H1

22.5 mm
M

Current technical model · Selection Guide ; Source row: 0.2; Source column: M

M12*1.5 mm
ΦA

Current technical model · Selection Guide ; Source row: 0.5~1; Source column: ΦA

78 mm
ΦB

Current technical model · Selection Guide ; Source row: 0.5~1; Source column: ΦB

28 mm
ΦD

Current technical model · Selection Guide ; Source row: 0.5~1; Source column: ΦD

62 mm
E

Current technical model · Selection Guide ; Source row: 0.5~1; Source column: E

10.57 mm
F

Current technical model · Selection Guide ; Source row: 0.5~1; Source column: F

6.5 mm
H

Current technical model · Selection Guide ; Source row: 0.5~1; Source column: H

24 mm
H1

Current technical model · Selection Guide ; Source row: 0.5~1; Source column: H1

22.5 mm
M

Current technical model · Selection Guide ; Source row: 0.5~1; Source column: M

M20*1.5 mm
ΦA

Current technical model · Selection Guide ; Source row: 2~10; Source column: ΦA

85 mm
ΦB

Current technical model · Selection Guide ; Source row: 2~10; Source column: ΦB

38 mm
ΦD

Current technical model · Selection Guide ; Source row: 2~10; Source column: ΦD

70 mm
E

Current technical model · Selection Guide ; Source row: 2~10; Source column: E

10.57 mm
F

Current technical model · Selection Guide ; Source row: 2~10; Source column: F

6.5 mm
H

Current technical model · Selection Guide ; Source row: 2~10; Source column: H

30 mm
H1

Current technical model · Selection Guide ; Source row: 2~10; Source column: H1

24 mm
M

Current technical model · Selection Guide ; Source row: 2~10; Source column: M

M30*1.5 mm
Input impedance

Current technical model · Technical parameters:; Source row: Input impedance

380±30Ω
Insulation impedance

Current technical model · Technical parameters:; Source row: Insulation impedance

≥5000MΩ(DC100V) MΩ
Material

Current technical model · Technical parameters:; Source row: Material

Stainless steel
Output impedance

Current technical model · Technical parameters:; Source row: Output impedance

350±10Ω
Rated load

Current technical model · Technical parameters:; Source row: Rated load

200KG、500KG、1000KG; 3T、5T、7.5T、10T
Safety overload

Current technical model · Technical parameters:; Source row: Safety overload

150%F.S
Sealing level

Current technical model · Technical parameters:; Source row: Sealing level

IP66
Sensitiveness

Current technical model · Technical parameters:; Source row: Sensitiveness

2.0 ±0.05 mV/V mV/V
Temperature range compensation

Current technical model · Technical parameters:; Source row: Temperature range compensation

-10~40℃ ℃
Ultimate Overload

Current technical model · Technical parameters:; Source row: Ultimate Overload

200%F.S
Zero point output

Current technical model · Technical parameters:; Source row: Zero point output

±1%F.S
temperature range

Current technical model · Technical parameters:; Source row: temperature range

-20~80℃ ℃
Voltage

Current technical model · Technical parameters:; Source row: voltage

10-15V(DC) V

Technical parameters

Rated load200KG、500KG、1000KG; 3T、5T、7.5T、10T
Comprehensive accuracy±0.1%F.S
Sensitiveness2.0 ±0.05 mV/V
Zero point output±1%F.S
Input impedance380±30Ω
Output impedance350±10Ω
Insulation impedance≥5000MΩ(DC100V) MΩ
voltage10-15V(DC) V
Temperature range compensation-10~40℃ ℃
temperature range -20~80℃ ℃
Safety overload150%F.S
Ultimate Overload 200%F.S
MaterialStainless steel
Sealing levelIP66
CableFour core shielded cable

Source selection table

measuring range( T)Corresponding size( mm)
ΦA mmΦB mmΦD mmE mmF mmH mmH1 mmM mm
0.2 T58 mm16 mm45 mm10.57 mm6.5 mm24 mm22.5 mmM12*1.5 mm
0.5~1 T78 mm28 mm62 mm10.57 mm6.5 mm24 mm22.5 mmM20*1.5 mm
2~10 T85 mm38 mm70 mm10.57 mm6.5 mm30 mm24 mmM30*1.5 mm