Controls and accessories · Controls and accessories series
ECA-CTB9
ECA-CTB9 belongs to Controls and accessories series in the Controls and accessories catalog.
ECA-CTB9 · Controls and accessories
Choose a control component by its role in the equipment and the signals it must exchange. Start with supply, input and output requirements and the exact suffix model.
Comparing ECA-CTB9
For ECA-CTB9, read A/D performance, Additional features, Analog signal output by the parameter group and variant shown. Check wiring and interface information for that variant. A shared series page does not establish interchangeability or compatibility with another component.
Parameters and where they apply
| A/D performance Current technical model · Technical parameters:; Source row: A/D performance | 24 bit, Delta Sigma method |
|---|---|
| Additional features Current technical model · Technical parameters:; Source row: Additional features | Can add TEDS function |
| Analog signal output Current technical model · Technical parameters:; Source row: Analog signal output | 4-20mA; 0-5V; 0-10V; Resolution of 1/3000 (optional) |
| Characteristics Current technical model · Technical parameters:; Source row: Characteristics | Zero point tracking, creep tracking, and adjustable analog quantities |
| Communication interface Current technical model · Technical parameters:; Source row: Communication interface | Rs232 and Rs485 are supported simultaneously; Modbus RTU protocol and free protocol |
| Display accuracy Current technical model · Technical parameters:; Source row: Display accuracy | 1/100000. |
| Excitation voltage output Current technical model · Technical parameters:; Source row: Excitation voltage output | 5V/DC, 100mA (up to 6 sensors with 350 Ω) V/DC |
| Gain drift Current technical model · Technical parameters:; Source row: Gain drift | ±5PPM/℃ |
| Input sensitivity Current technical model · Technical parameters:; Source row: Input sensitivity | 0.4~6mv/v mv/v |
| Maximum sampling frequency Current technical model · Technical parameters:; Source row: Maximum sampling frequency | Up to 4800Hz Hz |
| Nondimensional Current technical model · Technical parameters:; Source row: Nondimensional | 0.01% F.S. % |
| Optional model Current technical model · Selection guide:; Source row: CTB9; Source column: Optional model | Standard configuration |
| Optional model Current technical model · Selection guide:; Source row: CTB9; Source column: Optional model | A1 |
| Optional model Current technical model · Selection guide:; Source row: CTB9; Source column: Optional model | C1 |
| Optional model Current technical model · Selection guide:; Source row: CTB9; Source column: Optional model | C2 |
| Optional model Current technical model · Selection guide:; Source row: CTB9; Source column: Optional model | TS |
| Relative temperature Current technical model · Technical parameters:; Source row: Relative temperature | Temperature: 35 ℃~85% relative humidity Storage: 35-85% relative humidity ℃ |
| Remarks Description Current technical model · Selection guide:; Source row: CTB9; Source column: Remarks Description | Two relay outputs. 4-point input, 5-point transistor output |
| Remarks Description Current technical model · Selection guide:; Source row: CTB9; Source column: Remarks Description | Increase analog signal output |
| Remarks Description Current technical model · Selection guide:; Source row: CTB9; Source column: Remarks Description | Increase RS485 output |
| Remarks Description Current technical model · Selection guide:; Source row: CTB9; Source column: Remarks Description | Increase RS232 output |
| Remarks Description Current technical model · Selection guide:; Source row: CTB9; Source column: Remarks Description | Added TES calibration free function (sensors must have this function) |
| Sampling and output rate Current technical model · Technical parameters:; Source row: Sampling and output rate | 10. 40, 80, 120, 400, 600, 12001600, 4800 times/sec times/sec |
| Storage temperature Current technical model · Technical parameters:; Source row: Storage temperature | -25℃~+65℃ ℃ |
| Voltage withstand Current technical model · Technical parameters:; Source row: Voltage withstand | At 2000V AC50/60Hz for 1 minute V |
| Working temperature Current technical model · Technical parameters:; Source row: Working temperature | -30℃~+60℃ ℃ |
| Working voltage Current technical model · Technical parameters:; Source row: Working voltage | 12~30V/DC V/DC |
| Zero drift Current technical model · Technical parameters:; Source row: Zero drift | <0.02μV/℃ |
Technical parameters
| Working voltage | 12~30V/DC V/DC | |||||
|---|---|---|---|---|---|---|
| Input sensitivity | 0.4~6mv/v mv/v | |||||
| Excitation voltage output | 5V/DC, 100mA (up to 6 sensors with 350 Ω) V/DC | |||||
| Maximum sampling frequency | Up to 4800Hz Hz | |||||
| Zero drift | <0.02μV/℃ | |||||
| Gain drift | ±5PPM/℃ | |||||
| Nondimensional | 0.01% F.S. % | |||||
| Communication interface | Rs232 and Rs485 are supported simultaneously; Modbus RTU protocol and free protocol | |||||
| Display accuracy | 1/100000. | |||||
| Analog signal output | 4-20mA; 0-5V; 0-10V; Resolution of 1/3000 (optional) | |||||
| A/D performance | 24 bit, Delta Sigma method | |||||
| Sampling and output rate | 10. 40, 80, 120, 400, 600, 12001600, 4800 times/sec | |||||
| Storage temperature | -25℃~+65℃ ℃ | |||||
| Working temperature | -30℃~+60℃ ℃ | |||||
| Relative temperature | Temperature: 35 ℃~85% relative humidity Storage: 35-85% relative humidity ℃ | |||||
| Voltage withstand | At 2000V AC50/60Hz for 1 minute V | |||||
| Additional features | Can add TEDS function | |||||
| Characteristics | Zero point tracking, creep tracking, and adjustable analog quantities | |||||
Source selection table
| Instrument model | Optional model | Remarks Description | |||||
|---|---|---|---|---|---|---|---|
| CTB9 | Standard configuration | Two relay outputs. 4-point input, 5-point transistor output | |||||
| A1 | Increase analog signal output | ||||||
| C1 | Increase RS485 output | ||||||
| C2 | Increase RS232 output | ||||||
| TS | Added TES calibration free function (sensors must have this function) | ||||||
Talk to HTROBOT
- Emailemmy@htrobot.com
- Phone+86 152 0225 5004
- Alibaba storeVisit our Alibaba store